Boiler Module
Set |
|
|
Module Name |
Module Application |
|
BOIL2D |
Industrial Boiler Furnace |
|
BOILFD |
Boiler Furnace |
|
BOILST |
Stoker Furnace |
|
BOILTF |
Boiler with Twin Furnace Configuration |
|
BURNER |
Burner Elevation for a Fossil Fired Boiler |
|
BURNMF |
Burner Elevation for a FURNMF Boiler |
|
CAP |
Fuel Nozzle Cap |
|
CJUNC |
Cyclone Junction |
|
COUPLE |
Hydraulic Coupling |
|
CYCLON |
Cyclone Furnace |
|
DAMPER |
Air/Gas Damper |
|
DAMPRC |
Coal/Air Damper with Piping |
|
DAMPRN |
Parallel Dampers and Associated Ducting |
|
DCTBRN |
Duct Burner |
|
DMPRCN |
N Parallel Coal/Air Dampers |
|
DRNSEP |
Junction with Drain Separator |
|
DUCTFD |
Boiler Duct |
|
FAN |
Air/Gas Axial or Centrifugal Fan |
|
FANTAB |
Air/Gas Axial or Centrifugal Fan with Tabular Head Curves |
|
FEEDER |
Feeder |
|
GSFUEL |
HP Air/Gas Flowstream to Oil Flowstream
Converter |
|
HXAA |
Air Compressor Intercooler or Air-to-Air
Heat Exchanger |
|
HXAW |
Air Compressor Intercooler or Air-to
Water Heat Exchanger |
|
HXGAFD |
Tubular Air Heater-Boiler |
|
HXGM |
Metal Heat Sink |
|
HXGW |
Gas-to-Water Heat Exchanger |
|
JUNC |
Merging or Splitting Water or Steam
Flow Streams |
|
JUNCBA |
Air/Gas Junction |
|
JUNCBC |
Junction for Coal/Air Modules |
|
JUNCP |
Merge and Split Steam and/or Water Flow
Streams |
|
JUNCPA |
Junction for Combined Cycle Modules |
|
MOTORL |
Linear 3-Phase Electrical Motor |
|
OTF2FD |
Dual-Sided Once-Through Furnace |
|
OTFRFD |
Once-Through Single Furnace Boiler |
|
PIPE |
Steam/Water Pipe with Thermal Lag |
|
PIPEG |
Gas Pipe with Transport Delay |
|
PIPEQ |
Steam/Water Pipe with Thermal Lag |
|
PIPUR |
U-Rho Pipe |
|
PLATEN |
Platen Superheater or Enclosure in Fossil
Boilers |
|
PLNMRV |
Air or Gas Plenum (Reversing) |
|
PPNODE |
Multi-Node Pipe with Heat Transfer |
|
PULVBR |
Ball-and-Race or Roll-and-Race Pulverizer |
|
PULVEX |
Pulverizer with Exhauster |
|
REBOIL |
Steam Heated Reboiler |
|
RELIEF |
Relief Valve |
|
RESIST |
Piping Resistance Where the Thermal Delay
Effects Are Not Important |
|
RHT3FD |
3-Region Regenerative Air Heater with
Pressure-Flow Dynamics |
|
RHTRFD |
Regenerative Air Heater with
Pressure-Flow Dynamics |
|
RSISTG |
Air/Gas Flow Resistance |
|
SAHXFD |
Steam-Coil Air Heater |
|
SAHXMT |
Steam-Coil Air Heater with Drain Tank |
|
SPRSRP |
Gas to Steam/Water Heat Exchanger with
Intertwined Tubes |
|
SUPER |
Fossil Superheater or Reheater |
|
SUPHTR |
Multi-Node Superheater, Reheater, or
Economizer |
|
SUPUR |
U-Rho Superheater |
|
SUSPTR |
Startup Separator Tank with Air |
|
TANKEQ |
Equilibrium Tank with Air |
|
VALV3C |
General Purpose Converging Three-Way
Valve |
|
VALVE |
Steam/Water, or Two-Phase Valve with
Associated Piping and Actuator |
|
VALVEC |
Choking Valve for Compressible Steam Flow |
|
VALVEF |
Flashing Valve for Water or Steam/Water
Mixtures |
|
VALVEG |
Air or Gas Valve |
|
VALVEH |
Steam, Water, or Two-Phase Valve and
Associated Piping without Actuator Icon |
|
VALVEM |
Steam, Water, or Two-Phase Valve and
Associated Piping with Motor Actuator Icon |
|
VALVEN |
Parallel Steam/Water Valves |
|
VALVEO |
Oil Valve |
|
VALVER |
Pressure Regulating Valve |
|
VALVGN |
N Parallel Air or Gas Valves |
|
VALVGR |
Gas Pressure Regulating Valve |
|
VLVTAB |
Steam, Water, or Two-Phase Valve with
Tabular Valve Characteristic |
|
VSEP |
Vertical Separator |